wasp fuel polishing onsite servicingTo ensure the efficient and optimum running of your system, we highly recommend you service and replace some of your system particulars every 12 months.

The primary aim of the filter is to clear any foreign contaminants from the fuel to ensure the fuel is as pure as possible. The filter element (within blue and grey filter) collects the contaminates so it is important these are back washed regularly to clear out the contaminates to avoid blockages. The filters can be back washed up to five times before the element should be replaced. Regardless, the elements should be replaced on an annual basis or if they show any signs of wear and tear.

We also recommend you check the quality of your gaskets every 6 months and replace every 12 -36 months or at first signs of wear and tear.

Separate to the regular service, the system will flag if it requires any servicing or spare parts. This is via its built in automatic monitoring system. 

Your annual service should include:

Grey Filter

  • Element Replacement  (Part required- see table below)
  • Check gasket and replace if required (Part required- see table above)
  • Drain water

Blue Filter

  • Replace element (Part required- see table above)
  • Check gasket and replace if required (Part required- see table above)
  • Drain water

The required spare parts for regular servicing are as follows:

  W-PFS-010 W-PFS-014 W-PFS-026 W-PFS-040 W-PFS-060

Primary (grey filter) Element Part No

01030

01830

01830

04030

04060s

Primary (grey filter) Seal Kit Part No

10528

30979

30979

30980

30980

Final (blue filter) Element Part No

W-FCF-15-ELE

W-FCF-15-ELE

W-FCF-25-ELE

W-FCF-60-ELE

W-FCF-60-ELE

Final (blue filter) Lid seal

Part No

W-FCF-15-GK

W-FCF-15-GK

W-FCF-25/60-GKV

W-FCF-25/60-GKV

W-FCF-25/60-GKV

 

note iconNOTE

In the event during the service that air gets trapped in the system and the filters and input pipe work is not completely full of fuel, the filters will need to be bled of air and system primed.

 